By Sarah Bagnall, CEng, MRes, BEng, MIMMM, Director R-Tech Consultancy Services 

Material: 
A106 Grade B.

Environment: 
Nozzle contained both steam and process water used for both heating and cooling.

Operating Pressure: 
10 bar.

Operating Temperature: 
185oC.

Corrosion Mechanism:  
Stereomicroscopy revealed localised ‘Mesa’ type attack of the weld area along the internal surface. Analysis of the corrosion deposit revealed the presence of iron carbonate. Mechanism was deduced to 
be CO2 Corrosion.

Editor’s Notes

The economic impact of CO2 corrosion is well-documented, prompting the industry to implement various mitigation strategies over the years. However, as exploration expands into new fields with higher temperatures, pressures, and diverse fluid compositions, it is crucial to continuously assess and improve the corrosion resistance of both existing and new materials.

In the oil and gas industry, the presence of carbon dioxide (CO2) in fields poses a significant challenge due to its potential to cause severe corrosion, especially when water is present. While dry CO2 in either gas phase or supercritical fluid form is not corrosive to metals and alloys, the introduction of water-containing fluids leads to the formation of carbonic acid, which can rapidly corrode infrastructure.

The extent of CO2-induced corrosion is influenced by several key factors: Concentration of CO2 (and other components like H2S), 
Water Chemistry, Operating Conditions, Material Type.

Picture 1: Nozzle Extracted from a Heat Exchanger Vessel Due to Pinhole.

Picture2: Internal Surface of Pinhole Location.

Picture 3: Internal Surface of Circumferential Weld, Detailing Localised Attack

Picture 4. Internal Surface of Circumferential Weld, Detailing Localised Attack

Follow us on social media

General Enquiries

Institute of Corrosion
Corrosion House
5 St Peters Gardens
Marefair
Northampton
NN1 1SX

tel: + 44 (0)1604 438222
e-mail: admin@icorr.org

Related News

President Handover

President Handover

Dear Members, The Institute of Corrosion (ICorr) is very pleased to announce the successful election of Dr Yunnan Gao as its New President and Dr Anthony Setiadi as its New Vice President at its AGM held in Neville Hall, Newcastle on 13th November 2024. Dr Yunnan Gao...

Institute of Corrosion 2024 AGM at Neville Hall

Institute of Corrosion 2024 AGM at Neville Hall

“The Institute offers its many congratulations to our newly elected President – Dr Yunnan Gao”
At the AGM of November 13th held at NE Branch, Stephen Tate passed on the Presidency of ICorr to Yunnan Gao and Yunnan passed on the Vice-Presidency to Anthony Setiadi.
Yunnan brings a wealth of experience to ICorr in many areas of Corrosion Management and has the full support of Council and employer bp.
Anthony also joins with considerable experience in many areas including renewables and Offshore Wind in his extensive work with Wood Thilsted. Together our new Team will move forward with renewed success.